{"id":12916,"date":"2014-09-10T12:00:54","date_gmt":"2014-09-10T11:00:54","guid":{"rendered":"http:\/\/www.smartheating.cz\/sr\/smart-300-kw\/"},"modified":"2017-11-22T11:06:00","modified_gmt":"2017-11-22T10:06:00","slug":"smart-300-kw","status":"publish","type":"page","link":"https:\/\/www.smartheating.cz\/sr\/smart-300-kw\/","title":{"rendered":"SMART 300 kW"},"content":{"rendered":"<div class=\"row \"><div class=\"col-lg-3 col-md-3 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-2600\"><h3 class=\"line\">Automatski kotlovi<br \/>\n na biomasu (150\u2013500-1500 kW)<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-60-kw\/\">SMART&nbsp;60 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-80-kw\/\">SMART&nbsp;80 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-100-kw\/\">SMART&nbsp;100 kW<\/a><\/li>\n<li><a title=\"SMART 150 kW\" href=\"https:\/\/www.smartheating.cz\/en\/smart-150-kw\/\">SMART 150 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-180-kw\/\">SMART 180 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-200-kw\/\">SMART&nbsp;200 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-220-kw\/\">SMART 220 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-250-kw\/\">SMART&nbsp;250 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-300-kw\/\">SMART&nbsp;300 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-350-kw\/\">SMART&nbsp;350 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-400-kw\/\">SMART&nbsp;400 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-450-kw\/\">SMART&nbsp;450 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/smart-500-kw\/\">SMART&nbsp;500 kW<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Konfigurator&nbsp; boja<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/sr\/konfigurator-boja\/\">Izaberite boje kotlova<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Preuzimanje<\/h3>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/brozura_kotle_RS_nahled.pdf\">Bro\u0161ura &#8211; Smart kotlovi 150-500-1500 kW<\/a><br \/>\n <a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Biomass_Boilers_60-100kW_brochure_RS_nahled.pdf\">Bro\u0161ura &#8211; Smart kotlovi 60-100 kW<\/a><\/p>\n<h3 class=\"line\">Promotivni Magazin Sa Referencama 2017\/2018<\/h3>\n<p><a href=\"http:\/\/www.youblisher.com\/p\/1850659-Marketing-Reference-Book-2017-2018-Serbia\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/309\/1850659\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2017-2018 - Serbia\"><\/a><\/p>\n<h3 class=\"line\">Foto galerija<\/h3>\n<p><a href=\"https:\/\/www.smartheating.cz\/sr\/reference-evropa\/\">Pogledajte fotografije na\u0161ih instalacija<\/a><\/p>\n<\/div><\/div><div class=\"col-lg-9 col-md-9 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-1197\"><h1 class=\"title\"><span class=\"mezera-dole-0\">Automatski kotlovi <br \/>\nna biomasu<br \/>\n<\/span><strong>SMART\u00a0300 kW<\/strong><\/h1>\n<p><span class=\"obrazek-pod-textem\"><span style=\"color: #da1b1a; font-size: xx-large;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-25263 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_RS.png\" width=\"899\" height=\"448\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_RS.png 899w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_RS-300x149.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_RS-768x383.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_RS-600x299.png 600w\" sizes=\"auto, (max-width: 899px) 100vw, 899px\" \/><\/span><\/span><\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<br \/>\n\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p style=\"text-align: left;\"><span class=\"barva-modra\"><span class=\"barva-modra\">\u2022 Potpuno automatski, ekolo\u0161ki kotlovi sa odli\u010dnim performansama \u2022 Fleksibilno tehni\u010dko re\u0161enje \u2022 Razli\u010dite vrste goriva \u2022 Ekonomski i ekolo\u0161ki \u2022 9 vrsta kotlova \u2022 Efikasnost 96% \u2022 Pode\u0161avanja izlazne snage 30-100 % \u2022 Lambda sonda \u2022 Opcija sa kerami\u010dkim gorionikom \u2022 Opcija sa vibriraju\u0107om plo\u010dom gorionika \u2022 Minimalni zahtevi za odr\u017eavanje i servis \u2022 Regulacija grejnih krugova \u2022 Kaskadna instalaciona re\u0161enja \u2022 Daljinska kontrola i upravljanje preko mobilnog telefona i interneta \u2022 Mobilna re\u0161enja u kontejneru \u2022 Specijalna oprema za kotlove<\/span><\/span><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td width=\"66%\">\n<p>\u00a0\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-295\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1.jpg\" alt=\"rozcestnik-kotle-1\" width=\"567\" height=\"347\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-297\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2.jpg\" alt=\"rozcestnik-kotle-2\" width=\"567\" height=\"395\" \/><\/p>\n<\/td>\n<td width=\"1%\">\u00a0<\/td>\n<td width=\"33%\">\n<h3>Opis:<\/h3>\n<p><span style=\"font-size: 10pt;\">1.\u00a0\u00a0 Razdelni poklopac izme\u0111u<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0 ulaznog kanala i spremnika goriva<\/span><br \/>\n<span style=\"font-size: 10pt;\">2.\u00a0\u00a0 Spremnik goriva<\/span><br \/>\n<span style=\"font-size: 10pt;\">3.\u00a0\u00a0 Senzor nivoa goriva <\/span><br \/>\n<span style=\"font-size: 10pt;\">4.\u00a0\u00a0 Pokretni pod spremnika goriva<\/span><br \/>\n<span style=\"font-size: 10pt;\">5.\u00a0\u00a0 Pu\u017e za transport goriva<\/span><br \/>\n<span style=\"font-size: 10pt;\">6.\u00a0\u00a0 Primarni ventilator<\/span><br \/>\n<span style=\"font-size: 10pt;\">7.\u00a0\u00a0 Sekundarni ventilator<\/span><br \/>\n<span style=\"font-size: 10pt;\">8.\u00a0\u00a0 Prsten primarnog gorionika<\/span><br \/>\n<span style=\"font-size: 10pt;\">9.\u00a0\u00a0 Re\u0161etka \/ Vibriraju\u0107a plo\u010da<\/span><br \/>\n<span style=\"font-size: 10pt;\">10. Donji \/ gornji prsten gorionika<\/span><br \/>\n<span style=\"font-size: 10pt;\">11. Vatrostalna keramika<\/span><br \/>\n<span style=\"font-size: 10pt;\">12. Upravlja\u010dka jedinica Siemens<\/span><br \/>\n<span style=\"font-size: 10pt;\">13. Poklopac upravlja\u010dke jedinice <br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0 sa displejem<\/span><br \/>\n<span style=\"font-size: 10pt;\">14. Oprema<\/span><br \/>\n<span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u2013 Pi\u0161tolj za paljenje<\/span><br \/>\n<span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u2013\u00a0Mehanizam za hitno ga\u0161enje <\/span><br \/>\n<span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0 \u2013 Bezbednosni senzor toplote <\/span><br \/>\n<span style=\"font-size: 10pt;\">15. Za\u0161titni poklopac izmenjiva\u010da<br \/>\n<\/span><span style=\"font-size: 10pt;\">16. Izmenjiva\u010d toplote sa turbolatorima<\/span><br \/>\n<span style=\"font-size: 10pt;\">17. Posuda za pepeo ognji\u0161ta<\/span><br \/>\n<span style=\"font-size: 10pt;\">18. Posuda za pepeo izmenjiva\u010da<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0 \u2013 Opciono<\/span><br \/>\n<span style=\"font-size: 10pt;\">19. Produ\u017eetak dimnjaka<\/span><\/p>\n<p><span style=\"font-size: 10pt;\">20. Osigura\u010di<\/span><br \/>\n<span style=\"font-size: 10pt;\">21. Glavni prekida\u010d<\/span><br \/>\n<span style=\"font-size: 10pt;\">22. Mala servisna vrata<\/span><br \/>\n<span style=\"font-size: 10pt;\">23. Velika servisna vrata<\/span><br \/>\n<span style=\"font-size: 10pt;\">24. Re\u0161etka \/ Vibriraju\u0107a plo\u010da<\/span><br \/>\n<span style=\"font-size: 10pt;\">25. Kanal primarnog vazduha <\/span><br \/>\n<span style=\"font-size: 10pt;\">26. Pu\u017e za izbacivanje pepela<\/span><br \/>\n<span style=\"font-size: 10pt;\">27. Donja izolacija <\/span><br \/>\n<span style=\"font-size: 10pt;\">28. Donja izolacija izmenjiva\u010da<\/span><br \/>\n<span style=\"font-size: 10pt;\">29. Pu\u017e za izbacivanje pepela iz<br \/>\n\u00a0\u00a0\u00a0\u00a0\u00a0 izmenjiva\u010da &#8211; opciono<\/span><br \/>\n<span style=\"font-size: 10pt;\">30. Turbulatori<\/span><br \/>\n<span style=\"font-size: 10pt;\">31. Lambda sonda<\/span><br \/>\n<span style=\"font-size: 10pt;\">32. Dvostruka izolacija kotla<\/span><br \/>\n<span style=\"font-size: 10pt;\">33. Pogonski motor turbulatora<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<\/div><\/p>\n<table style=\"width: 691px;\">\n<tbody>\n<tr>\n<td style=\"width: 452.62px;\">\n<h2>Mogu\u0107e primene SMART kotlova:<\/h2>\n<p><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Stambene zgrade<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Vi\u0161enamenski objekti<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Sportski kompleksi<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Proizvodni pogoni, industrijski objekti i skladi\u0161ni prostor<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Op\u0161tinske zgrade<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Hoteli \/ Moteli \/ Wellness centri \/ Bazeni \/ Sportske arene<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022 <\/strong><\/span><span class=\"barva-modra\">\u0160kole, bolnice, policija i vojni kompleksi<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Gradske \u010detvrti<\/span><\/p>\n<\/td>\n<td style=\"width: 10px;\">&nbsp;<\/td>\n<td style=\"width: 224px;\">\n<h2>Novi elementi<\/h2>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong> <\/span><span class=\"barva-modra\">Kerami\u010dki gorionik<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1210\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\" alt=\"\" width=\"160\" height=\"129\"><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong> <span class=\"barva-modra\">Vibriraju\u0107a plo\u010da gorionika<\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1209\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\" alt=\"\" width=\"160\" height=\"99\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg 1000w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-300x186.jpg 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-600x372.jpg 600w\" sizes=\"auto, (max-width: 160px) 100vw, 160px\" \/><\/a><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>DIMENZIJE I TE\u017dINE KOTLOVA SMART 300\u2013500 kW<\/h2>\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29354 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_web_RS.png\" alt=\"\" width=\"949\" height=\"270\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_web_RS.png 949w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_web_RS-300x85.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_web_RS-768x219.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_web_RS-600x171.png 600w\" sizes=\"auto, (max-width: 949px) 100vw, 949px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\" border=\"0\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">A<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">B<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">C<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">E<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">F<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">G<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">H<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">CH&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2940<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2080<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2480<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">820<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1995<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1560<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1790<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">750<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">655<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<\/td>\n<td><span class=\"barva-cervena\" style=\"font-size: 10pt;\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/span><\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"height: 24px; text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\"><!--EndFragment-->T\u011a\u017dINA<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"svetla-bunka\" style=\"height: 24px; text-align: left;\"><span style=\"font-size: 10pt;\"><strong>Ognji\u0161te<\/strong><\/span><strong><span style=\"font-size: 10pt;\"> 300\u2013500 kW&nbsp;<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">1 550 kg<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\"><strong>Ukupna te\u017eina<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 24.74px;\">\n<td class=\"svetla-bunka\" style=\"height: 24.74px; text-align: left;\"><span style=\"font-size: 10pt;\"><strong>Izmenjiva\u010d <\/strong><\/span><strong><span style=\"font-size: 10pt;\">300 kW&nbsp;<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"height: 24.74px; text-align: center;\"><span style=\"font-size: 10pt;\">1 500 kg<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"height: 24.74px; text-align: center;\"><span style=\"font-size: 10pt;\">3 050 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"width: 896px; height: 0px;\">\n<tbody>\n<tr>\n<td style=\"width: 384px;\">&nbsp;<\/td>\n<td style=\"width: 5px;\">&nbsp;<\/td>\n<td style=\"width: 279.64px; text-align: center;\"><span class=\"barva-modra\" style=\"font-size: 10pt;\">Leva varijanta kotla<\/span><\/td>\n<td style=\"width: 212.36px; text-align: center;\"><span class=\"barva-modra\" style=\"font-size: 10pt;\">Desna varijanta kotla<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 384px;\">\n<p>&nbsp;<\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">1.<\/span> Izlaz vode DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">2.<\/span> Ulaz vode DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">3.<\/span> Ulazno \/ izlazni ventil vode ognji\u0161ta 3\/4\u201c <br \/>\n <\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">4.<\/span> <span style=\"font-size: small;\">Ulazno \/ izlazni ventil vode <\/span>izmenjiva\u010da toplote 3\/4\u201c<br \/>\n <\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5.<\/span> Pre\u010dnik dimnjaka&nbsp;300 mm<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5*<\/span> Opcija za ograni\u010dene prostore<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<\/td>\n<td style=\"width: 5px;\">&nbsp;<\/td>\n<td style=\"width: 492px;\" colspan=\"2\">\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29367\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_modra_rs.png\" alt=\"\" width=\"596\" height=\"295\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_modra_rs.png 695w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_modra_rs-300x148.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_modra_rs-600x297.png 600w\" sizes=\"auto, (max-width: 596px) 100vw, 596px\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>&nbsp;<\/h2>\n<h2 dir=\"LTR\" align=\"LEFT\">SERVISNE ZONE KOTLOVA 300\u2013500 kW<\/h2>\n<h2>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29393 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_modra_2.png\" alt=\"\" width=\"852\" height=\"442\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_modra_2.png 852w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_modra_2-300x156.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_modra_2-768x398.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_modra_2-600x311.png 600w\" sizes=\"auto, (max-width: 852px) 100vw, 852px\" \/><\/h2>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\" style=\"width: 258px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 220px; height: 24px; text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\">KARAKTERISTIKE SMART KOTLOVA<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek extra-tmavy-radek\" style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 220px; height: 24px;\" colspan=\"3\"><span style=\"font-size: 10pt;\">Tehni\u010dki podaci kotla<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Oznaka<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24.84px;\">\n<td style=\"width: 102.07px; height: 24.84px;\"><span style=\"font-size: 10pt;\">Nominalna snaga Ns<\/span><\/td>\n<td style=\"width: 37.93px; height: 24.84px; text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24.84px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Delimi\u010dna snaga Ds<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">75<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Efikasnost kotla pri Ns&nbsp;<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&gt;95&nbsp;<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Klasa kotla<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 220px; height: 24px;\" colspan=\"3\"><span style=\"font-size: 10pt;\">Voda<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Zapremina vode<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">l<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;690<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"svetla-bunka\" style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Pre\u010dnik priklju\u010dka za vodu<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&#8222;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Pre\u010dnik priklju\u010dka za vodu<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">DN<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;100<\/span><\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"width: 102.07px; height: 56px;\"><span style=\"font-size: 10pt;\">Hidrauli\u010dni gubici p\u0159i temperaturnom gradientu od 20\u00b0<\/span><\/td>\n<td style=\"width: 37.93px; height: 56px; text-align: center;\">\n<p><span style=\"font-size: 10pt;\">mbar&nbsp;<\/span><\/p>\n<\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 56px; text-align: center;\">\n<p><span style=\"font-size: 10pt;\">&nbsp;95<\/span><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura kotla <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;60\u201390\u00b0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Minimalna temperatura povratne vode <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Maksimalni radni pritisak <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">bar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Probni pritisak<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">bar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura ognji\u0161te<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">900\u20131100<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Pritisak u ognji\u0161tu<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">-0,04<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Potreban protok vazduha u dimnjaku<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Potreba za ve\u0161ta\u010dkim protokom vazduha u dimnjaku<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">Da<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura dimnih gasova pri NS <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,6<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura dimnih gasova pri Ds <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">63,1<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Pre\u010dnik cevi dimnjaka <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Pre\u010dnik dimnjaka <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">350<\/span><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 220px; height: 48px;\" colspan=\"3\"><span style=\"font-size: 10pt;\">Klasifikacija goriva prema normi EN 14961<\/span><\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"width: 102.07px; height: 72px;\"><span style=\"font-size: 10pt;\">Drveni pelet &#8211; C1<\/span><\/td>\n<td style=\"width: 37.93px; height: 120px; text-align: center;\" rowspan=\"2\"><span style=\"font-size: 10pt;\">Testirano gorivo<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 72px; text-align: center;\"><span style=\"font-size: 10pt;\">D6, M10, A1,5, DU90,0&nbsp;<\/span><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 102.07px; height: 48px;\"><span style=\"font-size: 10pt;\">Drvena se\u010dka &#8211; B1<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 48px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;P45, M30, A3.0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 220px; height: 24px;\" colspan=\"3\"><span style=\"font-size: 10pt;\">Elektri\u010dne instalacije<\/span><\/td>\n<\/tr>\n<tr style=\"height: 96px;\">\n<td style=\"width: 102.07px; height: 96px;\"><span style=\"font-size: 10pt;\">Elektri\u010dni priklju\u010dak<\/span><\/td>\n<td style=\"width: 37.93px; height: 96px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 96px; text-align: center;\"><span style=\"font-size: 10pt;\">3+N+PE 50Hz 230\/400V TN-C-S&nbsp;<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Motor transportera goriva<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Motor pu\u017ea<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Motor \u010dista\u010da izmenjiva\u010da (i)<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">2 x 550<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Motor za uklanjanje pepela <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Ventilator primarnog vazduha <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">66<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Ventilator sekundarnog vazduha 1<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\"><span style=\"font-size: 10pt;\">170<\/span><\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Ventilator sekundarnog vazduha 2<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\"><span style=\"font-size: 10pt;\">170<\/span><\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Izduvni ventilator dimnjaka <\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1100<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Elektri\u010dno paljenje<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1600<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Mehanizam razdelnog poklopca&nbsp;&nbsp;<\/span><\/td>\n<td style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 102.07px; height: 24px;\"><span style=\"font-size: 10pt;\">Ukupno<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"width: 37.93px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"width: 80px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4762,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<td>\n<table class=\" tabulka\" style=\"width: 469px;\">\n<tbody>\n<tr class=\"extra-tmavy-radek\" style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 83px; height: 24px; text-align: center;\">&nbsp;<\/td>\n<td class=\"extra-tmava-bunka\" style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"width: 273.66px; height: 24px; text-align: center;\" colspan=\"4\"><span style=\"font-size: 10pt;\">SMART 300<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"width: 125.34px; height: 72px; text-align: center;\" colspan=\"2\" rowspan=\"2\"><span style=\"font-size: 10pt;\"><strong><span style=\"font-size: 10pt;\"><b>AUTOMATSKI KOTLOVI NA BIOMASU <\/b>SMART 300<\/span><\/strong><\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 150.66px; height: 24px; text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Drveni pelet<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 123px; height: 24px; text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Drvena se\u010dka<\/span><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td class=\"tmava-bunka\" style=\"width: 90.66px; height: 48px; text-align: center;\"><span style=\"font-size: 10pt;\">Nominalna Vrednost<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 60px; height: 48px; text-align: center;\"><span style=\"font-size: 10pt;\">Minimalna Vrednost<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 63px; height: 48px; text-align: center;\"><span style=\"font-size: 10pt;\">Nominalna Vrednost<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"width: 60px; height: 48px; text-align: center;\"><span style=\"font-size: 10pt;\">Minimalna Vrednost<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek\" style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 399px; height: 24px;\" colspan=\"6\"><span style=\"font-size: 10pt;\">Izmerene vrednosti<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Nominalni toplotni kapacitet<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura dimnih gasova<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">92,5<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">64,2<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">63,1<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Potro\u0161nja goriva<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kg\/h<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">67,15<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">16,42<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">75,50<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">18,70<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura ulazne vode<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">56,7<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">60,0<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">59,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">57,4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura izlazne vode<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">73,3<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">75,8<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">74,7<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">75,0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura vode za hla\u0111enje&nbsp; <\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">9,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">11,1<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;9,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">11,0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Protok vode za hla\u0111enje<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/h<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">15,234<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,873<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">16,850<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,720<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Protok dimnjaka<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">Pa<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">130,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">130,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Temperatura okoline <\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">24,4<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">21,5<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">26,4<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">23,6<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Relativna vla\u017enost vazduha<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">42,9<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">43,7<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">46,9<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">47,2<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Atmosferski pritisak <\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kPa<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,20<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,10<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 399px; height: 24px;\" colspan=\"6\"><span style=\"font-size: 10pt;\">Analiza dimnih gasova <\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Kiseonik O<sub>2<\/sub><\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">7,12<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">11,32<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">7,11<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">11,68<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Ugljen-dioksid CO<sub>2<\/sub><\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">11,66<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">9,13<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">12,35<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">8,44<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Ugljen-monoksid CO<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">59<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">155<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">63<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">180<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Vi\u0161i ugljovodonici OGC<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">6<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">7<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\"><span style=\"font-size: small;\">Azotni oksidi NOx<\/span><\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">80<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">87<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Pra\u0161ina<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">35<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">31<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">25<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">41<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 399px; height: 24px;\" colspan=\"6\"><span style=\"font-size: 10pt;\">O2 = 10%&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Ugljen-monoksid CO<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px;\"><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">58<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">220<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">63<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">265<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Vi\u0161i ugljovodonici OGC<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px;\"><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\"><span style=\"font-size: small;\">Azotni oksidi NOx<\/span><\/span><\/td>\n<td style=\"width: 42.34px; height: 24px;\"><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">130<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">129<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">142<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">116<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Pra\u0161ina<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px;\"><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">27<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;35<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;20<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 399px; height: 24px;\" colspan=\"6\"><span style=\"font-size: 10pt;\">Pomoc\u0301ne vrednosti sagorevanja (\u010dvrsta goriva)<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Maseni protok gasova<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kg\/sec<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,196<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,060<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,191<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,066<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Stehiometrijska vrednost kiseonik<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,958<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,957<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,832<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,830<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Stehiometrijska vrednost vazduha<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,560<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,558<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,963<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,950<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Stehiometrijski volumen suvih dimnih gasova<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,449<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,446<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,883<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,871<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Stehiometrijski vazduh<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1,50<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">2,14<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1,50<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">2,23<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Volumen suvih dimnih gasova<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">7,254<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">9,245<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">6,088<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">8,857<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Volumen H<sub>2<\/sub>O u vazduha za sagorevanje<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,091<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,111<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,099<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,124<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Volumen H<sub>2<\/sub>O u dimnim gasovima<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,946<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,966<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,945<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,971<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Maksimalna koli\u010dina CO<sub>2<\/sub><\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">19,37<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">19,36<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"extra-tmava-bunka\" style=\"width: 399px; height: 24px;\" colspan=\"6\"><span style=\"font-size: 10pt;\">Izra\u010dunate vrednosti toplote<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Gubici toplote preko dimnih gasova (dimnjak)<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,6<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">4,7<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Gubici gasa zbog nesagorevanja<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Gubici zbog mehani\u010dkog nesagorevanja<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,3<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,6<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Gubici zbog prenosa toplote u okolinu<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,7<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1,8<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">0,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">1,4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Ukupni gubici<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">5,4<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">5,6<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">5,5<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">5,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24.41px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24.41px;\"><span style=\"font-size: 10pt;\">Efikasnost &#8211; indirektna metoda<\/span><\/td>\n<td style=\"width: 42.34px; height: 24.41px; text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24.41px; text-align: center;\"><span style=\"font-size: 10pt;\">94,6<\/span><\/td>\n<td style=\"width: 60px; height: 24.41px; text-align: center;\"><span style=\"font-size: 10pt;\">94,4<\/span><\/td>\n<td style=\"width: 63px; height: 24.41px; text-align: center;\"><span style=\"font-size: 10pt;\">94,5<\/span><\/td>\n<td style=\"width: 60px; height: 24.41px; text-align: center;\"><span style=\"font-size: 10pt;\">94,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Toplotna snaga <\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">308,8<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">75,5<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">322,7<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">80,0<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Toplotni kapacitet<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">293,6<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">71,8<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">307,1<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">76,4<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Nesigurnost pri odre\u0111ivanju toplotnog kapaciteta<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">% +\/-&nbsp;<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">12,3<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,0<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">12,9<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">3,2<\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Efikasnost &#8211; direktna metoda<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">%<\/span><\/strong><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,1<\/span><\/strong><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,0<\/span><\/strong><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,2<\/span><\/strong><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,5<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td class=\"tmava-bunka\" style=\"width: 83px; height: 24px;\"><span style=\"font-size: 10pt;\">Kapacitet \/ nominalna snaga<\/span><\/td>\n<td style=\"width: 42.34px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"width: 90.66px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">97,9<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">23,9<\/span><\/td>\n<td style=\"width: 63px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">102,4<\/span><\/td>\n<td style=\"width: 60px; height: 24px; text-align: center;\"><span style=\"font-size: 10pt;\">25,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Foto galerija<\/h2>\n<p>ngg_shortcode_0_placeholder\n <\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-h1-full.php","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-12916","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/pages\/12916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/comments?post=12916"}],"version-history":[{"count":0,"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/pages\/12916\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.smartheating.cz\/sr\/wp-json\/wp\/v2\/media?parent=12916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}