{"id":38616,"date":"2014-09-10T12:03:16","date_gmt":"2014-09-10T11:03:16","guid":{"rendered":"http:\/\/www.smartheating.cz\/smart-450-kw\/"},"modified":"2018-07-10T15:42:47","modified_gmt":"2018-07-10T14:42:47","slug":"smart-450-kw","status":"publish","type":"page","link":"https:\/\/www.smartheating.cz\/ja\/smart-450-kw\/","title":{"rendered":"SMART 450 kW"},"content":{"rendered":"<div class=\"row \"><div class=\"col-lg-3 col-md-3 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-2600\"><h3 class=\"line\">Automatic Biomass <br \/>\nBoilers (150\u2013500\u20131500 kW)<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-60-kw\/\">SMART&nbsp;60 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-80-kw\/\">SMART&nbsp;80 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-100-kw\/\">SMART&nbsp;100 kW<\/a><\/li>\n<li><a title=\"SMART 150 kW\" href=\"https:\/\/www.smartheating.cz\/en\/smart-150-kw\/\">SMART 150 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-180-kw\/\">SMART 180 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-200-kw\/\">SMART&nbsp;200 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-220-kw\/\">SMART 220 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-250-kw\/\">SMART&nbsp;250 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-300-kw\/\">SMART&nbsp;300 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-350-kw\/\">SMART&nbsp;350 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-400-kw\/\">SMART&nbsp;400 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-450-kw\/\">SMART&nbsp;450 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/smart-500-kw\/\">SMART&nbsp;500 kW<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Colour Configurator<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/en\/colour-configurator\/\"><span lang=\"EN-GB\">Configurate Your Own Boiler Colours<\/span><\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Download<\/h3>\n<p><a href=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/06\/Smart-Biomass-Boilers-150-500-kW-Brochure-1.pdf\" target=\"_blank\" rel=\"noopener\">Smart Boiler Brochure 150-500-1500 kW<\/a><br \/>\n<a href=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Letak_60-100kW_ENG_A4.pdf\">Smart Boiler Brochure 60-100 kW<\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Marketing Book 2018\/2019<\/h3>\n<p><a href=\"http:\/\/smartheatingtechnology.com\/marketing-book-usa\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/332\/1990555\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2018-2019 - ENG\"><\/a><\/p>\n<p><a href=\"http:\/\/smartheatingtechnology.com\/marketing-book-america\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/323\/1935492\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2018-2019 - America\"><\/a><\/p>\n<p><a href=\"http:\/\/smartheatingtechnology.com\/marketing-book-scotland\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/313\/1873995\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2017-2018 - Scotland\"><\/a><\/p>\n<p><a href=\"http:\/\/smartheatingtechnology.com\/marketing-book-canadian\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/256\/1533485\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2017-2018 - Canada\"><\/a><\/p>\n<p><a href=\"http:\/\/smartheatingtechnology.com\/marketing-book-ireland\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/332\/1991316\/200x300.jpg\" alt=\"Marketing &amp; Reference Book 2018-2019 - Ireland\"><\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Photo Gallery:<\/h3>\n<p><a href=\"https:\/\/www.smartheating.cz\/en\/reference-evropa\/\"><span lang=\"EN-GB\">Please, see photos from our installations<\/span><\/a><\/p>\n<\/div><\/div><div class=\"col-lg-9 col-md-9 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-1200\"><h1 class=\"title\"><span class=\"mezera-dole-0\">Automatick\u00e9 kotle<br \/>\n na biomasu <br \/>\n <\/span><strong>SMART 450 kW<\/strong><\/h1>\n<p><span class=\"obrazek-pod-textem\"><span style=\"color: #da1b1a; font-size: xx-large;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-24490 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_CZ.png\" width=\"899\" height=\"448\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_CZ.png 899w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_CZ-300x149.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_CZ-768x383.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_CZ-600x299.png 600w\" sizes=\"auto, (max-width: 899px) 100vw, 899px\" \/><\/span><\/span><\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<br \/>\n \u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p class=\"subtitle\">\u00a0<\/p>\n<p style=\"text-align: left;\"><span class=\"barva-modra\">\u2022\u00a0Pln\u011b automatick\u00e9, ekologick\u00e9 kotle s\u00a0vynikaj\u00edc\u00edmi vlastnostmi \u2022\u00a0Flexibilita technick\u00e9ho \u0159e\u0161en\u00ed\u00a0\u2022\u00a0Variabilita pou\u017eiteln\u00fdch paliv\u00a0\u2022\u00a0Ekonomick\u00fd a ekologick\u00fd provoz\u00a0\u2022\u00a0Dev\u011bt v\u00fdkonov\u00fdch \u0159ad\u00a0\u2022\u00a0\u00da\u010dinnost kotl\u016f 96%\u00a0\u2022\u00a0Modulace v\u00fdkonu v\u00a0rozsahu<br \/>\n 30 \u2013 100 %\u00a0\u2022\u00a0Lambda sonda\u00a0\u2022\u00a0Varianta keramick\u00e9ho sek\u010dn\u00edho ho\u0159\u00e1ku\u00a0\u2022\u00a0Varianta vibra\u010dn\u00edho litinov\u00e9ho ro\u0161tu\u00a0\u2022\u00a0N\u00edzk\u00e9 n\u00e1roky na \u00fadr\u017ebu a servis za\u0159\u00edzen\u00ed\u00a0\u2022\u00a0\u0158\u00edzen\u00ed topn\u00fdch okruh\u016f\u00a0\u2022\u00a0\u0158e\u0161en\u00ed kask\u00e1dov\u00fdch instalac\u00ed\u00a0\u2022\u00a0Kontrola mobiln\u00edm telefonem\u00a0\u2022\u00a0Kontrola p\u0159es internet \u2022\u00a0Mobiln\u00ed kontejnerov\u00e9 \u0159e\u0161en\u00ed\u00a0\u2022\u00a0Dostupn\u00e9 speci\u00e1ln\u00ed p\u0159\u00edslu\u0161enstv\u00ed<\/span><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 60%;\" width=\"66%\">\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u00a0\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-295 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530.jpg\" alt=\"rozcestnik-kotle-1\" width=\"443\" height=\"345\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530.jpg 443w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530-300x233.jpg 300w\" sizes=\"auto, (max-width: 443px) 100vw, 443px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-297 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658.jpg\" alt=\"rozcestnik-kotle-2\" width=\"459\" height=\"392\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658.jpg 459w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658-300x256.jpg 300w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><\/p>\n<\/td>\n<td style=\"width: 1%;\" width=\"1%\">\u00a0<\/td>\n<td style=\"width: 50%;\" width=\"33%\">\n<h3>Popis:<\/h3>\n<p><span style=\"font-size: 10pt;\">1.\u00a0\u00a0 Odd\u011blovac\u00ed klapka kan\u00e1lu<br \/>\n \u00a0\u00a0\u00a0\u00a0\u00a0 a\u00a0meziz\u00e1sobn\u00edku paliva<\/span><br \/>\n <span style=\"font-size: 10pt;\">2.\u00a0\u00a0 Meziz\u00e1sobn\u00edk paliva<\/span><br \/>\n <span style=\"font-size: 10pt;\">3.\u00a0\u00a0 Hladinov\u00e9 \u010didlo paliva<\/span><br \/>\n <span style=\"font-size: 10pt;\">4.\u00a0\u00a0 Pohybliv\u00e1 podlaha v\u00a0meziz\u00e1sobn\u00edku paliva<\/span><br \/>\n <span style=\"font-size: 10pt;\">5.\u00a0\u00a0 \u0160nekov\u00fd podava\u010d paliva<\/span><br \/>\n <span style=\"font-size: 10pt;\">6.\u00a0\u00a0 Prim\u00e1rn\u00ed ventil\u00e1tor spalov\u00e1n\u00ed<br \/>\n <\/span><span style=\"font-size: 10pt;\">7.\u00a0\u00a0 Sekund\u00e1rn\u00ed ventil\u00e1tory spalov\u00e1n\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">8.\u00a0\u00a0 Prstenec prim\u00e1rn\u00edho ho\u0159\u00e1ku<\/span><br \/>\n <span style=\"font-size: 10pt;\">9.\u00a0\u00a0 Ro\u0161tovac\u00ed\/Vibra\u010dn\u00ed litinov\u00fd ro\u0161t<\/span><br \/>\n <span style=\"font-size: 10pt;\">10.\u00a0Spodn\u00ed\/Horn\u00ed prstenec ho\u0159\u00e1ku<\/span><br \/>\n <span style=\"font-size: 10pt;\">11.\u00a0\u017d\u00e1ruvzdorn\u00fd n\u00edzkoemisn\u00ed deflektor<\/span><br \/>\n <span style=\"font-size: 10pt;\">12.\u00a0\u0158\u00edd\u00edc\u00ed jednotka Siemens<\/span><br \/>\n <span style=\"font-size: 10pt;\">13.\u00a0Kryt \u0159\u00edd\u00edc\u00ed jednotky s displayem<\/span><br \/>\n <span style=\"font-size: 10pt;\">14.\u00a0P\u0159\u00edslu\u0161enstv\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u2013\u00a0Horkovzdu\u0161n\u00e1 zapalovac\u00ed pistole<\/span><br \/>\n <span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u2013\u00a0Nouzov\u00e9 zah\u00e1\u0161ec\u00ed za\u0159\u00edzen\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0 \u2013 Bezpe\u010dnostn\u00ed teplotn\u00ed \u010didla<\/span><br \/>\n <span style=\"font-size: 10pt;\">15.\u00a0Odd\u011blovac\u00ed klapka v\u00fdm\u011bn\u00edku <br \/>\n \u00a0\u00a0\u00a0\u00a0\u00a0 pro \u0159\u00edzen\u00ed toku spalin<\/span><br \/>\n <span style=\"font-size: 10pt;\">16.\u00a0Tepeln\u00fd v\u00fdm\u011bn\u00edk s\u00a0turbul\u00e1tory<\/span><br \/>\n <span style=\"font-size: 10pt;\">17.\u00a0Popeln\u00edk spalovac\u00ed komory<\/span><br \/>\n <span style=\"font-size: 10pt;\">18.\u00a0Popeln\u00edk tepeln\u00e9ho v\u00fdm\u011bn\u00edku\u00a0<\/span><br \/>\n <span style=\"font-size: 10pt;\">\u00a0\u00a0\u00a0\u00a0\u00a0 \u2013 Doporu\u010den\u00e9 p\u0159\u00edslu\u0161enstv\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">19.\u00a0Kom\u00ednov\u00e1 n\u00e1dstavba<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt;\">20.\u00a0Pojistky<\/span><br \/>\n <span style=\"font-size: 10pt;\">21.\u00a0Hlavn\u00ed vyp\u00edna\u010d<\/span><br \/>\n <span style=\"font-size: 10pt;\">22.\u00a0Mal\u00e9 servisn\u00ed dve\u0159e spalovac\u00ed komory<\/span><br \/>\n <span style=\"font-size: 10pt;\">23.\u00a0Velk\u00e9 servisn\u00ed dve\u0159e spalovac\u00ed komory<\/span><br \/>\n <span style=\"font-size: 10pt;\">24.\u00a0Ro\u0161tovac\u00ed\/Vibra\u010dn\u00ed litinov\u00fd ro\u0161t<\/span><br \/>\n <span style=\"font-size: 10pt;\">25.\u00a0Slot vzduchu prim\u00e1rn\u00edho spalov\u00e1n\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">26.\u00a0\u0160neky vyn\u00e1\u0161en\u00ed popele ze spalovac\u00ed\u00a0komory<\/span><br \/>\n <span style=\"font-size: 10pt;\">27.\u00a0Spodn\u00ed izolace spalovac\u00ed komory<br \/>\n \u00a0\u00a0\u00a0\u00a0 \u00a0a tepeln\u00e9ho v\u00fdm\u011bn\u00edku<\/span><br \/>\n <span style=\"font-size: 10pt;\">28.\u00a0Spodn\u00ed \u017e\u00e1ruvzdorn\u00e1 izolace interi\u00e9ru<br \/>\n \u00a0\u00a0\u00a0\u00a0 \u00a0tepeln\u00e9ho v\u00fdm\u011bn\u00edku<\/span><br \/>\n <span style=\"font-size: 10pt;\">29.\u00a0\u0160nek vyn\u00e1\u0161en\u00ed popele ztepeln\u00e9ho <br \/>\n \u00a0\u00a0\u00a0\u00a0\u00a0 v\u00fdm\u011bn\u00edku \u2013 Doporu\u010den\u00e9 p\u0159\u00edslu\u0161enstv\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">30.\u00a0Turbul\u00e1tory pro vysokoefektivn\u00ed p\u0159enos<br \/>\n \u00a0\u00a0\u00a0\u00a0\u00a0 tepeln\u00e9 energie a \u010dist\u011bn\u00ed v\u00fdm\u011bn\u00edku<\/span><br \/>\n <span style=\"font-size: 10pt;\">31.\u00a0Lambda sonda<\/span><br \/>\n <span style=\"font-size: 10pt;\">32.\u00a0Dvojit\u00e1 izolace kotle se speci\u00e1ln\u00ed text\u00edli\u00ed<\/span><br \/>\n <span style=\"font-size: 10pt;\">33.\u00a0Pohon Turbul\u00e1tor\u016f<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<\/div><\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"66%\">\n<h2>SMART Boilers Application Options:<\/h2>\n<p><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Apartment Buildings<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Multifunctional Buildings<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Shopping Centres<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Production Plants &amp; Industrial Premises &amp; Storage Premises<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Agriculture &amp; Aquaculture &amp; Horticulture Farms<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Hotels\/Motels\/Wellness Centres\/Pools\/<\/span><span class=\"barva-modra\">Sport Arenas<br \/>\n <\/span><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Municipality Buildings<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Schools, Hospitals, Police &amp; Army Complexes<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">City Districts<\/span><\/p>\n<\/td>\n<td width=\"1%\">&nbsp;<\/td>\n<td width=\"33%\">\n<h2>&nbsp;New design features<\/h2>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong> <\/span><span class=\"barva-modra\">Ceramic Burner<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1210\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\" alt=\"\" width=\"160\" height=\"129\"><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong>&nbsp;<\/span><span class=\"barva-modra\">Vibrating Burner Plate<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1209\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\" alt=\"\" width=\"160\" height=\"99\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg 1000w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-300x186.jpg 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-600x372.jpg 600w\" sizes=\"auto, (max-width: 160px) 100vw, 160px\" \/><\/a><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>DIMENSIONS AND WEIGHTS OF TECHNOLOGIES 300\u2013500 kW<\/h2>\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-38529\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_cervene_web_JP.png\" alt=\"\" width=\"863\" height=\"246\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_cervene_web_JP.png 949w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_cervene_web_JP-300x85.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_cervene_web_JP-768x219.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_cervene_web_JP-600x171.png 600w\" sizes=\"auto, (max-width: 863px) 100vw, 863px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\" border=\"0\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">A<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">B<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">C<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">E<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">F<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">G<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">H<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">CH&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2940<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2440<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2840<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1180<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1995<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1560<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1790<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">750<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">655<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<\/td>\n<td><span class=\"barva-cervena\" style=\"font-size: 10pt;\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/span><\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\"><!--EndFragment-->WEIGHTS<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><strong><span style=\"font-size: 10pt;\">Burning chambre 300\u2013500 kW<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">1 550 kg<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">Total weight<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><strong><span style=\"font-size: 10pt;\">Exchanger 450 kW&nbsp;<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1 800 kg<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3 350 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"height: 0px; width: 896px;\">\n<tbody>\n<tr>\n<td style=\"width: 385px;\">&nbsp;<\/td>\n<td style=\"width: 5px;\">&nbsp;<\/td>\n<td style=\"text-align: center; width: 279px;\">&nbsp;<span class=\"barva-modra\" style=\"font-size: 10pt;\">Left sided<\/span><\/td>\n<td style=\"text-align: center; width: 212px;\"><span class=\"barva-modra\" style=\"font-size: 10pt;\">Right sided<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 385px;\">\n<p>&nbsp;<\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">1.<\/span> Water <span style=\"font-size: small;\">outlet <\/span>DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">2.<\/span> Water inlet DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">3.<\/span> In\/out water valve 3\/4\u201c <br \/>\n &nbsp;&nbsp;&nbsp; of burning chamber<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">4.<\/span> In\/out water valve 3\/4\u201c<br \/>\n &nbsp;&nbsp;&nbsp; of heat exchanger<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5.<\/span> Chimney outlet<br \/>\n &nbsp;&nbsp;&nbsp; avg.&nbsp;300 mm<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5*<\/span> Option for limited spaces<\/span><\/p>\n<\/td>\n<td style=\"width: 5px;\">&nbsp;<\/td>\n<td style=\"width: 491px;\" colspan=\"2\">\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-38538\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_JP.png\" alt=\"\" width=\"596\" height=\"295\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_JP.png 695w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_JP-300x148.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_JP-600x297.png 600w\" sizes=\"auto, (max-width: 596px) 100vw, 596px\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>&nbsp;<\/h2>\n<h2 dir=\"LTR\" align=\"LEFT\">SERVICE ZONES OF TECHNOLOGIES 300\u2013500 kW<\/h2>\n<h2>&nbsp;<\/h2>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-38601 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_JP2.png\" alt=\"\" width=\"852\" height=\"442\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_JP2.png 852w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_JP2-300x156.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_JP2-768x398.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Rozmerova_specifikace_JP2-600x311.png 600w\" sizes=\"auto, (max-width: 852px) 100vw, 852px\" \/><\/h2>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\">SMART BOILERS OPERATING DATA<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Technical data of the boiler&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Marking<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Nominal power Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Partial load (power) Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">115<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Boiler efficiency at Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&gt;95&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Boiler class<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Water&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Water volume<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">l<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">850<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\"><span style=\"font-size: 10pt;\">Diameter of water connection<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;&#8220;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;4<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Diameter of water connection<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">DN<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Hydraulic-pressure drop of the boiler<\/span><br \/>\n <span style=\"font-size: 10pt;\">at the temperature fall 20\u00b0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mbar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">122<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Boiler temperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;60\u201390\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Minimal temperature of returnable water<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Maximal operational pressure<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Test pressure<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperature of furnace<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">900\u20131100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Pressure of furmace<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">-0,04<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Required draught of the chimney<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Requirement for the forced draught<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Combustion temperature at Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">98,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Combustion temperature at Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62,4<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Diameter of flue gas duct<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Diameter of chimney<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">350<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Fuel clasification according to norm EN 14961&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Wood pellets &#8211; C1<\/span><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\"><span style=\"font-size: 10pt;\">Testedfuel&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D6, M10, A1,5, DU90,0&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Wood chips &#8211; B1<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;P45, M30, A3.0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Electrical installation&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Electrical connection<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3+N+PE 50Hz 230\/400V TN-C-S&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Conveyor engine<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Feeding auger engine<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Exchanger cleaning engine (s)<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2 x 550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ash-removing engine<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Fan of primary air<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">66<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Fan of secondary air 1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Fan of secondary air 2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Chimney exhaust fan<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Electrical ignition<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1600<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Separation flap valve<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\"><span style=\"font-size: 10pt;\">Total<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4762,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr class=\"extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"4\"><span style=\"font-size: 10pt;\">SMART 450<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"2\" rowspan=\"2\"><span style=\"font-size: 10pt;\">AUTOMATIC BIOMASS<\/span><br \/>\n <span style=\"font-size: 10pt;\"><strong>BOILERS SMART 450<\/strong><\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Wood pellets<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Wood chips<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Rated<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimum<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Rated<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimum<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Measured values&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Rated heat capacity<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Combustion producttemperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">96,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">60,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">98,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Fuel consumption<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/hour<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">102,48<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,74<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">109,60<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,00<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Input water temperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">61,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">61,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">60,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">58,2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Outlet water temperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">80,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">76,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">73,6<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Cooling water temperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">10,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Cooling water flow rate<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/hod<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">21,349<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,729<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">24,613<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,843<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Draught behind boiler<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Pa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">194,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">190,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">26,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ambient temperature<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">29,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">28,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">24,6<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Relative air humidity<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">28,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">29,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">28,6<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Barometric pressure<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kPa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,20<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,02<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,07<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Flue gas analysis<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Oxygen O<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,52<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,48<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,30<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">10,25<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Carbon dioxide CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,05<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">10,58<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,74<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,75<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Carbon monoxide CO<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">128<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">89<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">176<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">160<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Higher hydrocarbons OGC<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">13<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Nitrogen dioxides <span style=\"font-size: small;\">NOx<\/span><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">72<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">106<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">73<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Dust<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">28<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">86<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">79<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">O2 = 10%<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Carbon monoxide CO<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">144<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">106<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">178<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">207<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Higher hydrocarbons OGC<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Nitrogen dioxides <span style=\"font-size: small;\">NOx<\/span><\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">111<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">174<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">151<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Dust<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">17<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;25<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">34<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Auxiliary combustion values (solid fuels) <br \/>\n <\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Mass flow rate gases<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/sec<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,316<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,072<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,290<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,077<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stoichiometric oxygen value<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,958<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,957<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,831<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,830<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stoichiometric air value<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,560<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,559<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,960<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,952<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stoichiometric volume of dry combustion products<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,448<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,448<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,881<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,873<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stoichiometric air multiple<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,67<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,70<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,52<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,96<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume of dry combustion products, actual<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,655<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,040<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,396<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,730<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume of H<sub>2<\/sub>O in the combustion air<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,078<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,072<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,070<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,093<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume of H<sub>2<\/sub>O in the combustion produts<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,933<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,927<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,916<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,917<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Maximum volume CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,00<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,37<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,36<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Calculated values &#8211; heat overview&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Loss of sensible heat of combustion products (chimney)<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Loss of gas underburning<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Loss of mechanical underburning<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Loss of heat transfer into the environment<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,7<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Total loss<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Efficiency &#8211; indirect method<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">96,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">95,9<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Heat input<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">471,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">104,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">468,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">107,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Heat capacity<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">450,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">100,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">449,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">102,7<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Uncertainty of determining heat capacity<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">% +\/-&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">18,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">18,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,3<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\"><strong>Efficiency &#8211; direct method<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>%<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>95,5<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>96,2<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>95,8<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>96,0<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Capacity \/ rated output<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">100,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">100,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">23,1<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><span class=\"hps\">Photo Gallery<\/span>:<\/h2>\n<p>ngg_shortcode_0_placeholder\n <\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-h1-full.php","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-38616","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/pages\/38616","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/comments?post=38616"}],"version-history":[{"count":0,"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/pages\/38616\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.smartheating.cz\/ja\/wp-json\/wp\/v2\/media?parent=38616"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}