{"id":5463,"date":"2014-09-10T12:00:54","date_gmt":"2014-09-10T11:00:54","guid":{"rendered":"http:\/\/www.smartheating.cz\/smart-300-kw-3\/"},"modified":"2018-04-27T10:29:57","modified_gmt":"2018-04-27T09:29:57","slug":"smart-300-kw","status":"publish","type":"page","link":"https:\/\/www.smartheating.cz\/it\/smart-300-kw\/","title":{"rendered":"IT &#8211; SMART 300 kW"},"content":{"rendered":"<div class=\"row \"><div class=\"col-lg-3 col-md-3 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-2600\"><h3 class=\"line\">Caldaie a biomassa <br \/>\n automatiche <br \/>\n (150\u2013500\u20131500 kW)<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-60-kw\/\">SMART 60 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-80-kw\/\">SMART 80 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-100-kw\/\">SMART 100 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-150-kw\/\">SMART 150 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-180-kw\/\">SMART 180 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-200-kw\/\">SMART&nbsp;200 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-220-kw\/\">SMART 220 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-250-kw\/\">SMART&nbsp;250 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-300-kw\/\">SMART&nbsp;300 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-350-kw\/\">SMART&nbsp;350 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-400-kw\/\">SMART&nbsp;400 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-450-kw\/\">SMART&nbsp;450 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/smart-500-kw\/\">SMART&nbsp;500 kW<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Configurazione colori<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/it\/konfigurator\/\">Scegliete I colori della vostra caldaia<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Da poter scaricare<\/h3>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Smart-Biomass-Boilers-150-500-kW-Brochure_IT.pdf\" target=\"_blank\" rel=\"noopener\">Opuscolo caldaie Smart 150-500-1500 kW<\/a><\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Letak_60-100kW_IT_A4_new_nahled.pdf\" target=\"_blank\" rel=\"noopener\">Opuscolo caldaie Smart 60-100 kW<\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Galleria Fotografica<\/h3>\n<p><a href=\"https:\/\/www.smartheating.cz\/it\/reference-evropa\/\">Vedasi foto degli impianti realizzati<\/a><\/p>\n<\/div><\/div><div class=\"col-lg-9 col-md-9 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-5482\"><h1 class=\"title\"><span class=\"mezera-dole-0\">Caldaie automatiche a biomassa&nbsp;<\/span><br \/>\n <strong>SMART 300 kW<\/strong><\/h1>\n<p><span class=\"obrazek-pod-textem\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-33368\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_IT.png\" alt=\"\" width=\"915\" height=\"456\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_IT.png 899w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_IT-300x149.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_IT-768x383.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/kotel_nove_paliva_IT-600x299.png 600w\" sizes=\"auto, (max-width: 915px) 100vw, 915px\" \/><\/span><\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<br \/>\n &nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: left;\"><span class=\"barva-modra\">\u2022 Caldaie completamente automatiche con eccellenti prestazioni \u2022 Soluzioni tecniche flessibili \u2022 Possiblilit\u00e0 di funzionamento con diversi combustibili \u2022 Funzionamento economico ed ecologico \u2022 Ben 9 modelli di caldaie \u2022 Resa del 96% \u2022 Modulazione dal 30\u2013100% \u2022 Sonda Lambda \u2022 Bruciatore in ceramica \u2022 Piatto bruciatore vibrante \u2022 Ridotta manutenzione \u2022 Termoregolazioni su tutti i circuiti e dispositivi di sicurezza e controllo \u2022 Cascate termiche sino a 2 MW \u2022 Telegestione tramite SmartPhone \u2022 Controllo tramite Internet su piattaforma iCloud personalizzata \u2022 Soluzioni in Container mobili trasportabili \u2022 Accessori speciali per la caldaia<br \/>\n <\/span><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 60%;\" width=\"66%\">\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-295 size-full\" src=\"http:\/\/www.sosenergygroup.it\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530.jpg\" alt=\"rozcestnik-kotle-1\" width=\"443\" height=\"345\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530.jpg 443w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1-e1410970440530-300x233.jpg 300w\" sizes=\"auto, (max-width: 443px) 100vw, 443px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-297 size-full\" src=\"http:\/\/www.sosenergygroup.it\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658.jpg\" alt=\"rozcestnik-kotle-2\" width=\"459\" height=\"392\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658.jpg 459w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2-e1410970494658-300x256.jpg 300w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><\/p>\n<\/td>\n<td style=\"width: 1%;\" width=\"1%\">&nbsp;<\/td>\n<td style=\"width: 50%;\" width=\"33%\">\n<h3>Descrizioni:<\/h3>\n<p><span style=\"font-size: 10pt;\">1.&nbsp;&nbsp; Valvola antincendio<br \/>\n 2.&nbsp;&nbsp; Sensore livello combustibile<br \/>\n 3.&nbsp;&nbsp; Contenitore intermedio combustibile<br \/>\n 4.&nbsp;&nbsp; Meccanismo movimento combustibile<br \/>\n 5.&nbsp;&nbsp; Coclea di dosaggio<br \/>\n 6.&nbsp;&nbsp; Ventilatore aria primario<br \/>\n 7.&nbsp;&nbsp; Ventilatori aria secondari<br \/>\n 8.&nbsp;&nbsp; Anello combustione primario<br \/>\n 9.&nbsp;&nbsp; Bruciatore con piatto vibrante<br \/>\n 10. Anello inferiore e superiore bruciatore<br \/>\n &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; in materiale fibroceramico<br \/>\n 11. Cappello riflettente fibroceramico<br \/>\n 12. Unit\u00e0 controllo Siemens<br \/>\n 13. Coperchio unit\u00e0 di controllo dotato di display<br \/>\n 14.&nbsp;Accessori<br \/>\n &nbsp;&nbsp;&nbsp;&nbsp; \u2013 elemento d\u2018accensione<br \/>\n &nbsp;&nbsp;&nbsp;&nbsp; \u2013 mecanismo di estinzione in emergenza<br \/>\n &nbsp;&nbsp; &nbsp; \u2013 sensori temperatura di sicurezza<br \/>\n 15. Servoazionamento sportello scambiatori<br \/>\n 16. Scambiatori di calore con turbulatori<br \/>\n 17. Cassetta ceneri camera di combustione<br \/>\n 18. Cassetta ceneri scambiatori &#8211; opzione<br \/>\n 19. Estensione camino<br \/>\n &nbsp;<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<p><span style=\"font-size: 10pt;\"><br \/>\n 20. Fusibili<br \/>\n 21. Interruttore principale<br \/>\n 22. Sportello piccolo di manutenzione<br \/>\n 23. Sportello grande di manutenzione<br \/>\n 24. Griglia\/mecanismo vibrante<br \/>\n 25. Canale aria primaria<br \/>\n 26. Coclea estrazione ceneri<br \/>\n 27. Isolazione base<br \/>\n 28. Isolazione alta temp. base scambiatori <br \/>\n 29. Opzione estrazione ceneri scambiatori<br \/>\n 30. Turbolatori<br \/>\n 31. Sonda Lambda<br \/>\n 32. Doppio isolazione caldaia <br \/>\n 33. Motore azionamento turbolatori<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<\/div><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"66%\">\n<h2>Caldaie SMART opzioni di applicazioni:<\/h2>\n<p><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Edifici con Appartamenti<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Edifici Multifunzionali<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Centri Commerciali<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Stabilimenti di produzione &amp; Industria &amp; Depositi<br \/>\n <\/span><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Aziende agricole &amp; Acquaculture &amp; Orticulture<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong>&nbsp;<\/span><span class=\"barva-modra\">Hotels\/Motels\/Centri Wellness\/Piscine<br \/>\n <\/span><span class=\"barva-modra\"><span class=\"barva-cervena\"><strong>\u2022 <\/strong><\/span>Palestre sportivi<br \/>\n <\/span><span class=\"barva-cervena\"><strong>\u2022 <\/strong><\/span><span class=\"barva-modra\">Edifici Comunali<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022&nbsp;<\/strong><\/span><span class=\"barva-modra\">Scuole, Ospedali, complessi di Polizia e Militari<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022 <\/strong><\/span><span class=\"barva-modra\">Quartieri Cittadini<\/span><\/p>\n<\/td>\n<td width=\"1%\">&nbsp;<\/td>\n<td width=\"33%\">\n<h2>Nuove caratteristiche:<\/h2>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong> <\/span><span class=\"barva-modra\">Bruciatore ceramico<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1210\" src=\"http:\/\/www.be-heating.be\/wp-content\/uploads\/2014\/07\/H_5.jpg\" alt=\"\" width=\"160\" height=\"129\"><\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022 <\/strong><span class=\"barva-modra\">Piatto di combustione a vibrazione<br \/>\n <\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1209\" src=\"http:\/\/www.be-heating.be\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\" alt=\"\" width=\"160\" height=\"99\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg 1000w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-300x186.jpg 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-600x372.jpg 600w\" sizes=\"auto, (max-width: 160px) 100vw, 160px\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>DIMENSIONI E PESI DEI MODELLI 300\u2013500 kW<\/h2>\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-34109\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_bezova_web_1-1.png\" alt=\"\" width=\"863\" height=\"246\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_bezova_web_1-1.png 949w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_bezova_web_1-1-300x85.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_bezova_web_1-1-768x219.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotle_bezova_web_1-1-600x171.png 600w\" sizes=\"auto, (max-width: 863px) 100vw, 863px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\" border=\"0\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">A<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">B<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">C<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">E<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">F<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">G<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">H<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">CH&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2940<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2080<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2480<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">820<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1995<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1560<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1790<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">750<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">655<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<\/td>\n<td><span class=\"barva-cervena\" style=\"font-size: 10pt;\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/span><\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\"><span style=\"font-size: small;\">PESI&nbsp;<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><span style=\"font-size: 10pt;\"><strong>Camera di combustione&nbsp;300\u2013500 kW&nbsp;<\/strong><\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">1 550 kg<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>Peso <span style=\"font-size: small;\">totale<\/span><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><span style=\"font-size: 10pt;\"><strong>Scambiatore 300 kW&nbsp;<\/strong><\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1 500 kg<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3 050 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"height: 0px;\" width=\"896\">\n<tbody>\n<tr>\n<td style=\"width: 45%;\" width=\"33%\">\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">1.<\/span> Uscita acqua DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">2.<\/span> Ingresso acqua DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">3.<\/span> Valvola acqua \u00be entrata\/uscita camera di combustione<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">4.<\/span> Valvola acqua \u00be entrata\/uscita scambiatore di calore<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5.<\/span>&nbsp;Scarico fumi 300 mm<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5*<\/span> Opzione per spazi limitati<\/span><\/p>\n<\/td>\n<td width=\"1%\">&nbsp;<\/td>\n<td colspan=\"2\" width=\"66%\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-34080 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_bezova_IT.png\" alt=\"\" width=\"695\" height=\"344\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_bezova_IT.png 695w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_bezova_IT-300x148.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/Kotel_prave_leve_provedeni_bezova_IT-600x297.png 600w\" sizes=\"auto, (max-width: 695px) 100vw, 695px\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>&nbsp;<\/h2>\n<h2 dir=\"LTR\" align=\"LEFT\">SPAZI PER CONDUZIONE E MANUTENZIONE 300\u2013500 kW<\/h2>\n<h2 dir=\"LTR\" align=\"LEFT\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-34210 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/rozmerova_specifikace_bezova2-1-e1518007635856.png\" alt=\"\" width=\"950\" height=\"439\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/rozmerova_specifikace_bezova2-1-e1518007635856.png 950w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/rozmerova_specifikace_bezova2-1-e1518007635856-300x139.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/rozmerova_specifikace_bezova2-1-e1518007635856-768x355.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/rozmerova_specifikace_bezova2-1-e1518007635856-600x277.png 600w\" sizes=\"auto, (max-width: 950px) 100vw, 950px\" \/><\/h2>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\">DATI DI FUNZIONAMENTO DELLE CALDAIE<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Dati tecnici delle caldaia<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Modello<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Potenza utile nominale Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Potenza utile a carico parziale Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Rendimento di caldaia a Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;%<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&gt;95&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Classe della caldaia<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Acqua<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Contenuto d\u2018acqua<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">l<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;690<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\"><span style=\"font-size: 10pt;\">Diametro degli attacchi idraulici<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">DN<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;4<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Perdita di carico della caldaia con salto di temperatura di 20\u00b0<\/span><\/td>\n<td style=\"text-align: center;\">\n<p><span style=\"font-size: 10pt;\">mbar<\/span><\/p>\n<\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\">\n<p><span style=\"font-size: 10pt;\">&nbsp;95<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura di caldaia<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;60\u201390\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Minima temperatura dell\u2019acqua di ritorno<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Massima pressione di funzionamento<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Pressione di prova<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura del focolare<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">900\u20131100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Pressione del focolare<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">-0,04<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Tiraggio del camino richiesto<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Necessit\u00e0 di tiraggio forzato<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><span class=\"hps\">S\u00ed<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura gas scarico a Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,6<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura gas scarico Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">63,1<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Diametro del raccordo camino<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Diametro della canna fumaria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">350<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Classificazione del combustibile in accordo alla norma EN 14961<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Pellet di legno C1<\/span><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\"><span style=\"font-size: 10pt;\"><span class=\"hps\">Combustibile in prova<\/span><\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D6, M10, A1,5, DU90,0&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Cippato di legno \u2013 B1<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;P45, M30, A3.0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Installazione elettrica<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Connessione elettrica<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3+N+PE 50Hz 230\/400V TN-C-S&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motore del trasportatore<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motore dell\u2018alimentatore<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motore del dispositivo di pulizia scambiatore<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2 x 550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motore delle coclee di rimozione delle ceneri<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventilatore dell\u2019aria primaria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">66<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventilatore 1 dell\u2019aria secondaria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventilatore 2 dell\u2019aria secondaria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Estrattore gas combusti al camino<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Accensione elettrica<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1600<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Valvola a farfalla<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\"><span style=\"font-size: 10pt;\">Totale<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4762,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr class=\"extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\">&nbsp;<\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"4\"><span style=\"font-size: 10pt;\">SMART 300<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"2\" rowspan=\"2\"><strong><span style=\"font-size: 10pt;\">Caldaie a biomassa<br \/>\n SMART 300<\/span><\/strong><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Pellets di legno<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Cippato di legno<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Nominale<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimo<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Nominale<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimo<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Valori misurati<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Potenza termica di targa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura gas scarico<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">92,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">64,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">63,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Consumo di combustibile<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/h<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">67,15<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">16,42<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75,50<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">18,70<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura acqua ingresso caldaia<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">56,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">60,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">59,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">57,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura dell&#8217;acqua in uscita<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">73,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">74,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura acqua raffreddamento <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;9,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Portata acqua raffreddamento<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/h<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">15,234<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,873<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">16,850<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,720<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Tiraggio in uscita caldaia<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Pa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura ambiente<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">24,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">21,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">26,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">23,6<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Umidit\u00e0 relativa dell\u2018aria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">42,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">43,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">46,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">47,2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Pressione barometrica<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kPa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,20<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,10<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Analisi dei gas di combustione<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ossigeno O<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,12<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,32<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,11<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,68<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Anidride carbonica&nbsp;CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,66<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,13<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">12,35<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,44<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ossido di carbonio CO<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">59<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">155<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">63<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">180<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Idrocarburi ad alto peso&nbsp;OGC<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Disossidi di azoto NOx<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">80<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">87<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Polveri<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">35<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">31<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">41<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">O2 = 10%&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ossido di carbonio CO<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">58<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">220<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">63<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">265<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Idrocarburi ad alto peso OGC<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Disossidi di azoto NOx<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">129<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">142<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">116<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Polveri<\/span><\/td>\n<td><span style=\"font-size: 10pt;\">&nbsp;mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;35<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;20<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Valori supplementari di combustione (combustibili solidi)<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Portata di massa dei gas<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/s<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,196<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,060<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,191<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,066<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume di ossigeno stechiometrico<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,958<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,957<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,832<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,830<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume di aria stechiometrica<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,560<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,558<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,963<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,950<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume stechiometrico dei gas secchi<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,449<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,446<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,883<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,871<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Moltiplicatore stechiometrico dell\u2018aria<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,50<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,14<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,50<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,23<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume effettivo dei gas secchi<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,254<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,245<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,088<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,857<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume d\u2019acqua nell\u2019aria comburente<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,091<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,111<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,099<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,124<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume d\u2019acqua nei prodotti di combustione<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,946<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,966<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,945<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,971<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volume massimo di &nbsp;CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,37<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,36<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Valori calcolati \u2013 prospetto calori <\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Perdita di calore sensibile dei gas combusti (perdita al camino)<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Perdita dei gas incombusti<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Perdita del prodotto incombusto<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,6<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Perdita per dispersione di calore nell\u2018ambiente<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Perdita totale<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Rendimento \u2013 metodo indiretto<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Calore in ingresso<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">308,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">75,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">322,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">80,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Calore reso<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">293,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">71,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">307,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">76,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Incertezza nella determinazione del calore reso<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">% +\/-&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">12,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">12,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\"><strong>Rendimento \u2013 metodo diretto<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">%<\/span><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,1<\/span><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,0<\/span><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,2<\/span><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">95,5<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Potenza resa\/Potenza targa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">97,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">23,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">102,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Galleria fotografica<\/h2>\n<p>ngg_shortcode_0_placeholder<\/p>\n<p><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-h1-full.php","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-5463","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/pages\/5463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/comments?post=5463"}],"version-history":[{"count":0,"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/pages\/5463\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.smartheating.cz\/it\/wp-json\/wp\/v2\/media?parent=5463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}