{"id":31871,"date":"2014-09-10T12:03:54","date_gmt":"2014-09-10T11:03:54","guid":{"rendered":"http:\/\/www.smartheating.cz\/smart-500-kw\/"},"modified":"2018-01-18T14:59:09","modified_gmt":"2018-01-18T13:59:09","slug":"smart-500-kw","status":"publish","type":"page","link":"https:\/\/www.smartheating.cz\/hr\/smart-500-kw\/","title":{"rendered":"SMART 500 kW"},"content":{"rendered":"<div class=\"row \"><div class=\"col-lg-3 col-md-3 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-2600\"><h3 class=\"line\">Automatski kotlovi <br \/>\n na biomasu <br \/>\n (150\u2013500\u20131500 kW)<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-60-kw\/\">SMART&nbsp;60 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-80-kw\/\">SMART&nbsp;80 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-100-kw\/\">SMART&nbsp;100 kW<\/a><\/li>\n<li><a title=\"SMART 150 kW\" href=\"https:\/\/www.smartheating.cz\/hr\/smart-150-kw\/\">SMART 150 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-180-kw\/\">SMART 180 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-200-kw\/\">SMART&nbsp;200 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-220-kw\/\">SMART 220 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-250-kw\/\">SMART&nbsp;250 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-300-kw\/\">SMART&nbsp;300 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-350-kw\/\">SMART&nbsp;350 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-400-kw\/\">SMART&nbsp;400 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-450-kw\/\">SMART&nbsp;450 kW<\/a><\/li>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/smart-500-kw\/\">SMART&nbsp;500 kW<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Konfiguratot boja<\/h3>\n<ul>\n<li><a href=\"https:\/\/www.smartheating.cz\/hr\/colour-configurator\/\"><span lang=\"EN-GB\">Konfiguriranje vlastitih boja kotlova<\/span><\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Download<\/h3>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/09\/brozura_kotle_RS_nahled.pdf\" target=\"_blank\" rel=\"noopener\">Bro\u0161ura Smart kotlovi<\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Smart Marketing <br \/>\n &amp; Knjiga Referenci 2017\/2018<\/h3>\n<p><a href=\"http:\/\/www.youblisher.com\/p\/1909322-Marketing-book-2017-2018\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"http:\/\/www.youblisher.com\/files\/publications\/319\/1909322\/200x300.jpg\" alt=\"Marketing book 2017\/2018\"><\/a><\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"line\">Fotogalerija:<\/h3>\n<p><a href=\"https:\/\/www.smartheating.cz\/hr\/reference-evropa\/\"><span lang=\"EN-GB\">Molimo pogledajte fotografije iz na\u0161ih instalacija<\/span><\/a><\/p>\n<\/div><\/div><div class=\"col-lg-9 col-md-9 col-xs-12 col-sm-12\"><div class=\"content_block\" id=\"custom_post_widget-1201\"><h1 class=\"title\"><span class=\"mezera-dole-0\"><span class=\"mezera-dole-0\">Automatski kotlovi <br \/>\n na biomasu<\/span><br \/>\n <\/span><strong>SMART&nbsp;500 kW<\/strong><\/h1>\n<p><span class=\"obrazek-pod-textem\"><span style=\"color: #da1b1a; font-size: xx-large;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-31876 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_HR.png\" alt=\"\" width=\"899\" height=\"448\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_HR.png 899w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_HR-300x149.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_HR-768x383.png 768w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/kotel_nove_paliva_HR-600x299.png 600w\" sizes=\"auto, (max-width: 899px) 100vw, 899px\" \/><\/span><\/span><\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<br \/>\n &nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p class=\"subtitle\">&nbsp;<\/p>\n<p style=\"text-align: left;\"><span class=\"barva-modra\"><span class=\"barva-modra\">\u2022 Potpuno automatizirani, ekolo\u0161ki prihvatljivi kotlovi s izvrsnim performansima \u2022 Fleksibilno tehni\u010dko rje\u0161enje \u2022 Mogu\u0107nost razli\u010ditih vrsta goriva \u2022 Ekonomi\u010dan i ekolo\u0161ki \u2022 9 kotlova \u2022 U\u010dinkovitost 96% \u2022 Izlazna modulacija 30-100% \u2022 Lambda senzor \u2022 Opcija kerami\u010dkog plamenika \u2022 Vibracijska plo\u010da plamenika \u2022 Niski zahtjevi za odr\u017eavanje i servisiranje \u2022 Regulacija krugova \u2022 Kaskadna instalacijska rje\u0161enja \u2022 Upravljanje mobilnim telefonom i internetom \u2022 Mobilna rje\u0161enja u kontejneru \u2022 Posebna oprema za kotlove<\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td width=\"66%\">\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-295\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-1.jpg\" alt=\"rozcestnik-kotle-1\" width=\"567\" height=\"347\"><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-297\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/rozcestnik-kotle-2.jpg\" alt=\"rozcestnik-kotle-2\" width=\"567\" height=\"395\"><\/p>\n<\/td>\n<td width=\"1%\">&nbsp;<\/td>\n<td width=\"33%\">\n<h3>Opis:<\/h3>\n<p><span style=\"font-size: 10pt;\">&nbsp;<br \/>\n 1. Razdjelni poklopac izme\u0111u ulaznog <br \/>\n &nbsp;&nbsp;&nbsp; kanala i spremnika goriva<br \/>\n 2. Spremnik za gorivo<br \/>\n 3. Senzor razine goriva<br \/>\n 4. Pomi\u010dni pod spremnika goriva<br \/>\n 5. Pu\u017eni (spiralni) transporteri za gorivo<br \/>\n 6. Primarni ventilator<br \/>\n 7. Sekundarni ventilator<br \/>\n 8. Primarni prsten plamenika<br \/>\n 9. Vrtlo\u017eni kota\u010d<br \/>\n 10. Gornji \/ donji prsten plamenika<br \/>\n 11. Vatrostalna keramika<br \/>\n 12. Upravlja\u010dka jedinica Siemens<br \/>\n 13. Poklopac upravlja\u010dke jedinice sa zaslonom<br \/>\n 14. Oprema<br \/>\n &#8211; Pi\u0161tolj za paljenje<br \/>\n &#8211; Mehanizam za hitno ga\u0161enje po\u017eara<br \/>\n &#8211; Sigurnosni senzori temperature<br \/>\n 15. Za\u0161titni poklopac izmjenjiva\u010da<br \/>\n 16. Izmjenjiva\u010d topline s turbulatorima<br \/>\n 17. Posuda za pepeo ognji\u0161ta<br \/>\n 18. Posuda za pepeo izmjenjiva\u010da-izborno<br \/>\n 19. Produ\u017eetak dimnjaka<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 10pt;\">20. Osigura\u010di<br \/>\n 21. Glavni prekida\u010d<br \/>\n 22. Mala servisna vrata<br \/>\n 23. Velika servisna vrata<br \/>\n 24. Re\u0161etkasti \/ vibracijski mehanizam<br \/>\n 25. Primarni zra\u010dni kanal<br \/>\n 26. Pu\u017eni transporter za pepeo<br \/>\n 27. Donja izolacija<br \/>\n 28. Donja izolacija izmjenjiva\u010da<br \/>\n 29. Pu\u017eni transporter za izbacivanje<br \/>\n &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; pepela iz izmjenjiva\u010da-izborno<br \/>\n 30. Turbulatori<br \/>\n 31. Lambda senzor<br \/>\n 32. Dvostruka izolacija kotla<br \/>\n 33. Turbulatori motora s pogonom<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<\/div><\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"66%\">\n<h2>Mogu\u0107nosti primjene SMART kotlova:<\/h2>\n<p><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Stambene zgrade<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Vi\u0161enamjenski objekti<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Trgova\u010dki centri<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Proizvodni pogoni, industrijske prostorije i skladi\u0161ta<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Objekti za poljoprivredu, hortikulturu, ribarstvo<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">H<\/span><span class=\"barva-modra\">oteli \/ moteli \/ wellness centri \/ bazeni \/ sportske dvorane<br \/>\n <\/span><span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Gradske zgrade<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">\u0160kole, bolnice, policijski i vojni kompleksi<\/span><br \/>\n <span class=\"barva-cervena\"><strong>\u2022<\/strong> <\/span><span class=\"barva-modra\">Gradske \u010detvrti<\/span><\/p>\n<\/td>\n<td width=\"1%\">&nbsp;<\/td>\n<td width=\"33%\">\n<h2>Nove zna\u010dajke dizajna<\/h2>\n<p><span class=\"barva-cervena\"><strong>&nbsp; \u2022<\/strong> <\/span><span class=\"barva-modra\">Kerami\u010dki plamenik<\/span><\/p>\n<p><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1210\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/H_5.jpg\" alt=\"\" width=\"160\" height=\"129\"><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"barva-cervena\"><strong>&nbsp; <\/strong><\/span><span class=\"barva-modra\"><span class=\"barva-cervena\"><strong>\u2022<\/strong>&nbsp;<\/span>Vibracijska plo\u010da plamenik<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1209\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg\" alt=\"\" width=\"160\" height=\"99\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4.jpg 1000w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-300x186.jpg 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/FFA_4-600x372.jpg 600w\" sizes=\"auto, (max-width: 160px) 100vw, 160px\" \/><\/a><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>DIMENZIJE I TE\u017dINE KOTLOVA SMART 300\u2013500 kW<\/h2>\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-309 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-2.png\" alt=\"smart-kw150-2\" width=\"863\" height=\"321\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-2.png 863w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-2-300x111.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-2-600x223.png 600w\" sizes=\"auto, (max-width: 863px) 100vw, 863px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\" border=\"0\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">A<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">B<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">C<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">E<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">F<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">G<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">H<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">CH&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2940<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2560<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2960<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1300<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1995<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1560<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1790<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">750<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">655<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/p>\n<\/td>\n<td><span class=\"barva-cervena\" style=\"font-size: 10pt;\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <\/span><\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\"><!--EndFragment-->TE\u017dINA<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><strong><span style=\"font-size: 10pt;\">Ognji\u0161te 300\u2013500 kW&nbsp;<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">1 550 kg<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><strong><span style=\"font-size: 10pt;\">Ukupna te\u017eina <\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\" style=\"text-align: left;\"><strong><span style=\"font-size: 10pt;\">Izmjenjiva\u010d 500 kW&nbsp;<\/span><\/strong><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1&nbsp;950 kg<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3 550 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"height: 0px; width: 896px;\">\n<tbody>\n<tr>\n<td style=\"width: 385px;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"width: 5px;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"text-align: center; width: 277px;\"><span class=\"barva-modra\" style=\"font-size: 10pt;\">Desna varijanta kotla<\/span><\/td>\n<td style=\"text-align: center; width: 214px;\"><span class=\"barva-modra\" style=\"font-size: 10pt;\">Lijeva varijanta kotla<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 385px;\">\n<p>&nbsp;<\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">1.<\/span>&nbsp;Izlaz vodet DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">2.<\/span> Ulaz vode DN100\/PN6<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">3.<\/span> Ulazni \/ izlazni ventil ognji\u0161ta 3\/4 &#8221; <\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">4.<\/span> Ulazni \/ odvodni ventil izmjenjiva\u010da <br \/>\n &nbsp;&nbsp;&nbsp; topline 3\/4 &#8220;<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5.<\/span>&nbsp;Promjer dimnjaka 300 mm<\/span><\/p>\n<p><span class=\"barva-modra\" style=\"font-size: 10pt;\"><span class=\"barva-cervena\">5*<\/span> Opcija za ograni\u010dene prostore<\/span><\/p>\n<\/td>\n<td style=\"width: 5px;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"width: 491px;\" colspan=\"2\">\n<p><span style=\"font-size: 10pt;\">&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-310 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-3.png\" alt=\"smart-kw150-3\" width=\"596\" height=\"280\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-3.png 596w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/07\/smart-kw150-3-300x140.png 300w\" sizes=\"auto, (max-width: 596px) 100vw, 596px\" \/><\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>&nbsp;<\/h2>\n<h2 dir=\"LTR\" align=\"LEFT\">SERVISNE ZONE SMART KOTLOVA 300\u2013500 kW<\/h2>\n<h2>&nbsp;<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1451 size-full\" src=\"http:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/rozmerova_specifikace.png\" alt=\"rozmerova_specifikace\" width=\"836\" height=\"418\" srcset=\"https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/rozmerova_specifikace.png 836w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/rozmerova_specifikace-300x150.png 300w, https:\/\/www.smartheating.cz\/wp-content\/uploads\/2014\/08\/rozmerova_specifikace-600x300.png 600w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><\/h2>\n<table>\n<tbody>\n<tr>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\"><span style=\"font-size: 10pt;\">SMART KOTLOVI KARAKTERISTIKE<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Tehni\u010dki podaci kotla<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Oznaka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Nominalna snaga Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Djelomi\u010dna snaga Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">140<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Efikasnost kotla pri Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&gt;95<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Klasa kotla<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Voda<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Koli\u010dina vode<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">l<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">900<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"svetla-bunka\"><span style=\"font-size: 10pt;\">Promjer priklju\u010dka za vodu<\/span><\/td>\n<td class=\"svetla-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&#8220;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Promjer priklju\u010dka za vodu<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">DN<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Hidrauli\u010dni pad tlaka kotla pri temperaturi od 20\u00b0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mbar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura kotla<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">60\u201390\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Minimalna temperatura povratne vode<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">55<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Maksimalni radni pritisak<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Probni pritisak<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">bar<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura ognji\u0161ta<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">900\u20131100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Pritisak u ognji\u0161tu <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">-0,04<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Potreban protok zraka u dimnjaku<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mbar&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Potreba za umjetnim protokom zraka u dimnjaku<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura izgaranja pri Pn<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">97,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Temperatura izgaranja pri Pp<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62,2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Promjer cijevi dimnjaka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">300<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Promjer dimnjaka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mm<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">350<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Klasifikacija goriva prema normi EN 14961 <\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Drveni pelet &#8211; C1<\/span><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\"><span style=\"font-size: 10pt;\">Testirano<br \/>\n gorivo&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">D6, M10, A1,5, DU90,0&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Drvena sje\u010dka &#8211; B1<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;P45, M30, A3.0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"3\"><span style=\"font-size: 10pt;\">Elektri\u010dne instalacije <\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Elektri\u010dni priklju\u010dak<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3+N+PE 50Hz 230\/400V TN-C-S&nbsp;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motor transportera goriva<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motor pu\u017enog transportera<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motor \u010dista\u010da izmjenjiva\u010da <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2 x 550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Motor za uklanjanje pepela<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">550<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventil primarnog zraka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">66<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventil sekundarnog zraka 1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventil sekundarnog zraka 2 <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">170<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Ventil za ispu\u0161ne plinove dimnjaka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1100<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Elektri\u010dno paljenje<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1600<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\">Mehanizam razdijelnog poklopca<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\"><span style=\"font-size: 10pt;\">Ukupno<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">W<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4762,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<td>\n<table class=\" tabulka\">\n<tbody>\n<tr class=\"extra-tmavy-radek\">\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"extra-tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"4\"><span style=\"font-size: 10pt;\">SMART 500<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka extra-tmava-bunka\" style=\"text-align: center;\" colspan=\"2\" rowspan=\"2\"><span style=\"font-size: 10pt;\"><strong>AUTOMATSKI KOTLOVI <br \/>\nNA BIOMASU SMART 500<\/strong><\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Drveni peleti<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\" colspan=\"2\"><span style=\"font-size: 10pt;\">Drvena sje\u010dka<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Rated<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimum<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Rated<\/span><\/td>\n<td class=\"tmava-bunka\" style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Minimum<\/span><\/td>\n<\/tr>\n<tr class=\"tmavy-radek\">\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Izmjerene vrijednosti<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Nominalni toplincki kapacitet<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">500<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura izgaranja proizvoda<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">97,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">59,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">98,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62,2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Potro\u0161nja goriva<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/hour<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">114,26<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">24,85<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">121,00<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27,12<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura ulazne vode<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">63,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">62,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">60,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">58,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura izlazne vode<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">82,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">77,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">76,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">73,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura vode za hla\u0111enje <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Protok vode za hla\u0111enje<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/hod<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">23,387<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,347<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27,200<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,550<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Protok dimnjaka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">Pa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">215,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">25,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">210,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">26,0<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Temperatura okoline<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">\u00b0C<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">30,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">29,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">24,9<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Relativna vla\u017enost zraka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">21,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">23,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Atmosferski tlak<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kPa<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,20<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,30<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">98,99<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">98,99<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Analiza dimnih plinova<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Kisik O<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8,99<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,53<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,36<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">9,77<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ugljikov dioksid CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">10,85<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,06<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">11,54<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">10,18<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ugljikov monoksid CO<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">151<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">67<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">214<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">153<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Vi\u0161i ugljikovodici OGC<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">16<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Du\u0161ikovi dioksidi NOx<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">ppm<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">56<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">78<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">112<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">81<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Pra\u0161ina<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">14<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">27<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">106<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">92<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">O2 = 10%<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ugljikov monoksid CO<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">173<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">68<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">216<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">188<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Vi\u0161i ugljikovodici OGC<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Du\u0161ikovi dioksidi NOx<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">105<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">130<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">185<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">162<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Pra\u0161ina<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">mg\/m<sup>3<\/sup><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">13<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;22<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">39<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">48<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Pomo\u0107ne vrijednosti sagorijevanja (\u010dvrsta goriva)<br \/>\n <\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Maseni protok plinova<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kg\/sec<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,356<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,076<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,323<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,081<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stehiometrijska vrijednost kisika<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,958<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,957<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,831<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,830<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stehiometrijska vrijednost zraka<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,560<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,559<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,959<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,952<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stehiometrijski volumen produkata sagorijevanja<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,448<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,448<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,880<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,873<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Stehiometrijski zrak<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,73<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,55<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,53<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">1,85<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volumen suhih proizvoda sagorijevanja <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,788<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,638<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">6,499<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">7,354<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volumen H<sub>2<\/sub>O u zraku sagorijevanja<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,073<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,059<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,060<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,053<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Volumen H<sub>2<\/sub>O u produktu sagorijevanja<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">m<sup>3<\/sup>\/kg<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,928<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,914<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,906<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,899<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Maksimalni volumen CO<sub>2<\/sub><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,01<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,37<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">19,36<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"extra-tmava-bunka\" colspan=\"6\"><span style=\"font-size: 10pt;\">Izra\u010dunate vrijednosti \u2013 pregled topline<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Gubitak topline preko dimnih plinova (dimnjak)<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,8<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Gubitak plinova zbog nesagorijevanja <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Gubitak zbog mehani\u010dkog nesagorijevanja<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Gubitak topline zbog prijenossa u okolinu<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">0,4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Ukupan gubitak <\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">2,7<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">5,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">3,7<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Efikasnost \u2013 indirektna metoda<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">97,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">94,8<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">96,3<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Input topline<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">525,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">114,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">517,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">116,1<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Kapacitet toplinske snage<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">kW&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">502,4<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">110,2<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">496,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">111,5<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Nesigurnost odre\u0111ivanja kapaciteta topline<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">% +\/-&nbsp;<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">21,1<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,6<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">20,9<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">4,7<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\"><strong>Efikasnost \u2013 direktna metoda<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>%<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>95,6<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>96,4<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>96,0<\/strong><\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\"><strong>96,1<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"tmava-bunka\"><span style=\"font-size: 10pt;\">Kapacitet \/ nomilni output<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">%<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">100,5<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,0<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">99,3<\/span><\/td>\n<td style=\"text-align: center;\"><span style=\"font-size: 10pt;\">22,3<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Fotogalerija:<\/h2>\n<p>ngg_shortcode_0_placeholder\n <\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-h1-full.php","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-31871","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/pages\/31871","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/comments?post=31871"}],"version-history":[{"count":0,"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/pages\/31871\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.smartheating.cz\/hr\/wp-json\/wp\/v2\/media?parent=31871"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}